Measures CO in air and finds CO sources.
Features:
- Fast enough to locate CO source in "walk-around" test
- Three pin sensor for better performance
- Long battery life
- Includes Pump (ACMP3)
- Auto-off can be disabled for data logging
- Select averaging or normal for smoothing or fast response to
change
- Range: 0 to 1000PPM (2000PPM with 5 minute max exposure
time)
- Initial accuracy: 0-15ppm ±5% reading ±1 ppm after
zeroing;15-35ppm ±5% reading ±2 ppm after zeroing; 0-1000ppm ±5%
reading ±5 ppm after zeroing
- Response time: <70sec to 90% of reading
- Operating temperature: 32 to 105 ºF
- Sensor type: Electrochemical (specific to CO)